29
CHARACTERISTICS
SG2 BODY COMPACT BASE
[ SG2-Sx-xxx-PP-E ]
SG2 BODY COMPACT MUTING
[ SG2-S/L/Tx-xxx-PP-W ]
SG4 BODY COMPACT BASE
[ SG4-Sx-xxx-PP-E ]
SG4 BODY COMPACT MUTING
[ SG4-S/L/Tx-xxx-PP-W ]
GENERAL DATA
Type (EN61496-1)
2
4
PL (EN ISO 13849-1)
d
e
SIL (IEC 61508)
2
3
Resolution
315 mm (4 beams)
415 mm (3 and 4 beams)
515 mm (2 beams)
Protected height
515 mm (2 beams)
815 mm (3 beams)
915 mm or 1215 (4 beams)
Operating distance
0.5 …50 m
Retroreflective muting arms
operating distance
(included in L and T versions)
---
0.5 … 3 m
---
0.5 … 3 m
Emitter-Receiver muting arms
operating distance
---
0.5 … 7 m
---
0.5 … 7 m
ELECTRICAL DATA
Power supply (Vdd)
24 Vdc ± 20%
Outputs
2 PNP
Output current
0.5 A max/each output
Capacitive load
65 nF max at 25°C
Response time
14 ... 16 ms depending on model
A
Cables length (for power supply)
50 m max.
MECHANICAL AND ENVIRONMENTAL DATA
Operating temperature
0 …+55 °C
Humidity
15 … 95 % (no condensation)
Mechanical protection
IP 65 (EN 60529)
FUNCTIONS
Test input
Manual/Automatic restart
External Device Monitoring (EDM)
Muting type
(Selectable with DIP-sw)
A
---
T-Muting/L-Muting
---
T-Muting/L-Muting
Muting time-out
(Selectanle with DIP-sw)
A
---
10 min. or ∞
---
10 min. or ∞
---
Override
---
Override
NOTES
A
For detailed informations refer to related Product Datasheet or Manual
SAFETY SENSORS
�
SG BODY COMPACT BASE